Casa " Blog " Conoscenza VCB " Interruttore automatico in vuoto ZN63(VS1)-24

Interruttore automatico in vuoto ZN63(VS1)-24

interruttore automatico sottovuoto 11kv

Generale

ZN63(VS1)indoor high-voltage alternating-current vacuum circuit breaker has a frequency of 50Hz and a rated voltage of 12kV.It applies tothe electrical equipment control and protection in industrial and mining enterprises,power plants and substations,particulanty to the places needingfrequent operation.It can be fixed in a switch cabinet or installed on a handcart.

With stable performance and convenient installation,it is the best choice for the control and protection of high-voltage power transmission

and distribution systems.

◆Product Standards

ZN63(VS1)indoor high-voltage alternating-current vacuum circuit breaker is produced in line with the following standards and codes.

● IEC 62271-100 High-voltage alternating-current circuit-breakers

● GB/T 11022-2011 Common specifications for high-voltage switchgear and controlgear standards

● GB 1984 High-voltage alternating-current circuit-breakers

● GB 311.1 Insulation co-ordination for high voltage transmission and distribution equipment

◆Operating conditions

Normal Operating Conditions

Temperatura ambiente: -40℃~+40℃ (sotto 35℃ entro 24 ore).

Umidità relativa: ≤95% (media giornaliera) o ≤90% (media mensile)

Altitudine: ≤1000m

◆Technical Parameters

1.1 Parametri tecnici

    Articolo Unità Valore di riferimento
    Tensione nominale kV 24
tensione di resistenza agli impulsi di fulmine kV 145
    Livello di isolamento nominale Tensione di resistenza alla frequenza di alimentazione di 1 minuto kV 65
    Frequenza nominale Hz 50/60
    Corrente nominale A 630/1250/1600/2000/2500/3150
    Corrente nominale di interruzione del cortocircuito kA 20/25/31.5
    Corrente nominale di cortocircuito (valore di picco) kA 506,380 
    Corrente nominale di breve durata kA 20/25/31.5/40
    Corrente di tenuta nominale (valore di picco) kA 506,380 
    Sequenza operativa richiesta   0-0,3s-CO-180s-CO
    Durata nominale del cortocircuito S 4
    Tempi di esecuzione-interruzione con la corrente nominale di cortocircuito I tempi 30
    Vita meccanica   Livello M2
    Pesare kg 150

◆Transformer capacity and fuse selection

●The fuse can cut off a large short-circuit current in less than 10 ms and its breaking current can be up to 50KA.Thus,it can protect the transformer most effectively.

● In terms of match between the transformer and the fuse (Table 1),the potential surge current of the fuse must be considered.Thus,fusingcurrent of the fuse must be 1.6 times of the rated value;designer must consider possible fluctuations of other parameters of the grid and reservemargins for them.If a fuse is selected for high-voltage motor protection,designer must consider frequency of start of the high-voltage motorbecause frequent starts of the high-voltage motor will result in the fuse’s failure when timely cooling is not available.

◆Fuse Selection

Tensione primaria di
il trasformatore (kV)
Capacità di
the transformer(kVA
Modello del fusibile Corrente nominale
of the fuse(A)
Modello per il mercato domestico Modello per il mercato internazionale
6.6 200 XRNT-10 12kV BDGHC 31.5
250 40
300/315 50
400 12kV BDGHC 63
500 80
630 90

◆Overall And Installation Dimension

Dimensioni complessive dell'interruttore sottovuoto per interni ad alta tensione a corrente alternata VF(R)-12 (su ruote)

interruttore automatico sottovuoto 11kv
Larghezza del mobile (mm) P(mm) A(mm) B(mm) C(mm) E(mm) φW(mm)
650 150 500 530 490 203 35
800 210 650 680 640 278 35
1000 275 850 880 840 378 35

◆Actuator Of VS1-24

The actuator employs spring energy storage which can be done electricallyor manually.When the circuit breaker is operating,the energy generated by theenergy stor

age spring is transferred to the connecting rod mechanism throughan output cam and then to the movable contact through the connecting rodmechanism.The advanced and appropriate buffer avoids bounces in breakingand reduces the impact and vibration in breaking.The actuator almost needsno maintenance or adjustment.It can operate for up to 10,000 times.

vacuum-circuit-breaker

◆Overall And Installation Dimension

Overall dimension of VS1-24(wheeled)embedded indoor high-voltage alternating-current vacuum circuit breaker

circuit-breaker
Corrente nominale (A) 630 1250 1600
Rated short-time withstand current(kA) 202,531.5  2,531.5  31.5
Dimensione del contatto fisso D(mm) φ35 φ49 φ55
Distanza interfase (mm)   275±1.5  
Drive travel(mm)   300±2  

 Overall dimension of VS1-24(fixed)indoor high-voltage alternating-current vacuum circuit breaker(large-current)

circuit-breaker
Corrente nominale (A) 2000 2500 3150
Rated short-time withstand current(kA) 31.5 31.5 31.5
Dimensione del contatto fisso D(mm) φ79 φ109 φ109
Distanza interfase (mm)   275±1.5  
Drive travel(mm)   300±2

 