Strona główna " Produkt " Złącze MC4 " Złącze fotowoltaiczne 1000V 1500V DC Moduł fotowoltaiczny PV-HCB40

Złącze fotowoltaiczne 1000V 1500V DC Moduł fotowoltaiczny PV-HCB40

1000V/1500V DC Solar PV Connector Solar Photovoltaic connector is one of the products crucial for completing the photovoltaic system. The connector will be used mainly for current transmission between the sun’s PV modules and the inverters, as well as other equipment. Its design is according to the latest PV-HCB40 standard, with regard to IEC62852:2014. It has excellent insulation and low resistance capabilities with a voltage level of up to 1500V DC, hence perfect for long-term stable power transmission.

SKU: Brak danych Kategoria:

Product Features and Benefits

13 Imported Contact Points Design: With tin-plated copper contacts, ideal for high elasticity and low resistance (contact resistance as low as 0.5mΩ) for improved current transmission efficiency.
Rated Voltage and Current: It supports 1000V/1500V DC and bears a rated current of 45A for suitable application in large-scale PV projects.
Ensures compliance with extreme safety norms. Compliant with the IEC62852:2014 Standard, it also possesses an IP68 protection rating ensuring safe operation under difficult conditions.
Functioning within -40° to +90°C maximum operational temperature +105°C for various climatic conditions
High flame retardant level wherein safety can be ensured even in high-temperature environments as it has a UL-94-V0.
Easy Snap-In Locking System: The connections are strong as well as easy to install quickly.

Process of Installing Solar PV Connectors

Preparation of DC Input Cables: The type of cable used should be of the same as is required by the connector.
Crush Positive and Negative Metal Terminals: Crimping tools are utilized in their installation by professionals. Now, insert the positive and negative connectors so that the terminals are inserted into the crimped terminals on the respective connectors.
Tighten the Connector Locking Nut Tighten the locking nut around the connector without overtorquing to prevent loosening of the lock after torque to some extent.
Measure Voltage and Insulation Resistance Measurement of the voltage- using multimeter, and insulation resistance- using an insulation resistance tester
Connect to the Inverter The connectors were plugged into the DC input terminals of the inverter.

Parametry produktu

Nr seryjny. Parametr Parametr
1 Typ Solar photovoltaic connector
2 Napięcie znamionowe 1000V DC
3 Prąd znamionowy 45A (2.5/4/6mm2,14/12/10AWG)
4 Napięcie testowe 8000V (50Hz, 1min)
5 Zakres temperatur -40°C ...+90°C
6 Górna temperatura graniczna +105°C
7 Stopień ochrony IP2X/ IP68
8 Rezystancja styku złączy wtykowych 0,5 mΩ
9 Klasa bezpieczeństwa
10 Materiał kontaktowy Miedź, ocynowana
11 Materiał izolacyjny PPO
12 Siła wycofująca/siła wprowadzająca ≥50N/≤50N
13 System blokujący Zatrzask
14 Klasa płomienia UL-94-V0
Process of Installing Solar PV Connectors 1500V DC Solar Photovoltaic
1500V DC Solar Photovoltaic 3 Solar Photovoltaic Connector Photovoltaic
1500V DC PV-HCB40 5 Process of Installing Solar PV Connectors

Installation Precautions

Exclude Sun and Rain During Installation: Protect the part from sun and rain during installation to avoid connector aging or rusting.
Professional Crimping Tool and Installer Training: Be equipped with professional crimping tool and provide professional training for the installation personnel on crimping operation.
Check Contact Resistance: The Contact resistance of the connector is to be checked to always be within predetermined normal range.
Prevent Polarity Errors: Check the polarity before connection and ensure that the positive pole and negative pole are correct.
Insulation Resistance Test: Insulation resistance tester check the cable’s insulation performance for safety.

FAQ (Frequently Asked Questions)

Q1: Are you a manufacturer or a trading company?
We are a manufacturer with over 9 years of experience.

Q2: How can I get a product quote?
You can send us an e-mail or contact our trade manager. We will reply within 1 hour during working hours .

Q3: How does your company control quality?
We use high-grade raw materials for all products; 2) Experienced workers have control over every detail of the process; 3) Our quality control department is responsible for inspection at every step of production.

Q4: Do you support OEM services?
We welcome OEM and ODM orders warmly and have abundant experience in the successful completion of OEM projects.

Q5: How can I get a sample?
We do provide free samples, but costs of the courier are usually borne by the buyer. In the event that you have a courier account, your courier can collect the samples.

Q6: How long to delivery?

1) For samples: 1-3 days; 2) For small orders: 3-10 days; 3) For large orders: 10-18 days.
Q7: Are your products certified?
Yes, we are ISO9001, RoHS, CE certified and so on. If you need other certifications, let us know, we will follow it accordingly.

Q8: Product quality is guaranteed?
Yes, we ensure quality for one year.

Q9: What are payment terms?
For payments up to USD 10,000: we require 100% advance payments. For payments above USD 10,000: we take 30% of T/T in advance, with balance before shipment or L/B.

Q10: How will you dispatch the items? Is it safe?
For small pieces we are using courier service from DHL, FedEx, UPS, etc. and for large ones through air or sea. We ensure good packaging for safety during transportation.